Know whether your structure contains chromium 6 before any sanding, blasting or demolition starts
SEEF takes samples on site, analyses them in its own laboratory and turns the results into concrete measures.
Our patented method measures chromium 6 even in paint that contains zinc.
How can we help?

Laboratory analysis
Hard-to-test materials such as zinc paint and insulation, analysed with our patented method. Report within 5 working days.
Submit samples
On-site investigation
Sampling on bridges, ships, plant and buildings by SEEF or IOM, followed by laboratory analysis and reporting.
Request a survey
Projects and advice
Safe working during maintenance, refurbishment and demolition, for asset owners, contractors and consultants.
Book an advice call
Products
Test kits and wipe sample sets for a first indication on site, plus the SEEF Chrome-6 Neutralizer.
Go to the shopOne partner, from sampling to solution
Investigation on site
- 01Intake and quoteWe go through the asset and planning with you and send a quote with a fixed price per sample.
- 02Sampling on sitePaint samples taken in line with the OGOS guideline, insulation sampled in multiple layers per location.
- 03Analysis in our own laboratoryQuantitative, using the SEEF method. Results within 5 working days of receipt as standard.
- 04Report and follow-up adviceFor each sampling point: the result, the assessment against limit values, and what it means for control measures and waste classification.
Also for exposure monitoring in line with NEN-EN 689 and chromium-6 in high-temperature insulation.
Chromium 6 recovered from zinc-containing paint
Percentage of the chromium 6 present that is recovered in the result
Source: 2026 comparative study with four external laboratories.
Reliable measurement where other methods fall short
Zinc and aluminium in paint can convert chromium 6 during analysis, so the measured value comes out lower than what the sample actually contains. Our patented method stabilises chromium 6 during extraction and greatly reduces this interference.

Reliable chromium 6 measurement in zinc-containing paint
Zinc-rich primers, shop primers and hot-dip galvanised steel often contain 2 to 8% zinc in practice. That is exactly where conventional methods measure too low. In a comparative study with four external laboratories, we recovered 97% of the chromium 6 present at 2% zinc. The best-performing other laboratory reached 52%. At 8% zinc, the figures were 87% and 32%.

Your chromium 6 results within 5 working days
The 5 working days start on the first working day after your samples arrive at our laboratory. Our in-house lab analyses more than 2,000 samples a month, so you don’t depend on anyone else’s schedule. Is it urgent, for example because of a shutdown or a remediation schedule? An express analysis is available on request. You register your samples and track their status in WeLIMS.

Laboratory analysis of paint, insulation, scrap metal and air samples
We analyse paint and coatings, insulation material, blasting grit, scrap metal and waste, as well as air and wipe samples. We use ICP-MS, GC-MS and UV-VIS instruments from Agilent Technologies. Besides chromium 6, we also measure other heavy metals. Our laboratory works in accordance with ISO/IEC 17025. Our application for accreditation is currently being assessed by the Dutch Accreditation Council (RvA).

Chromium 6 advice from survey to completion
A result on its own is not a plan. We help you turn the results into a remediation approach, a specification or work plan, and an update to your risk assessment. We can also advise on exposure monitoring in accordance with EN 689 and on classifying scrap metal as waste with the correct European waste code (EWC). If you wish, our specialists will support your project right through to completion. That way you take measures that match the actual risk, no more and no less.
ADVICE
Found chromium 6? Your next steps
Clients, asset managers and safety professionals come to us with questions like these. Our advice matches the risk: no measures you don’t need, and no risks left unaddressed.