{"id":5961,"date":"2026-04-06T08:30:11","date_gmt":"2026-04-06T06:30:11","guid":{"rendered":"https:\/\/seefbv.com\/en\/docs\/waarom-crvi-analyse-in-droge-verf-andere-analyse-vereist\/"},"modified":"2026-06-30T14:15:51","modified_gmt":"2026-06-30T12:15:51","password":"","slug":"why-crvi-analysis-in-dry-paint-other-analysis-required","status":"publish","type":"docs","link":"https:\/\/seefbv.com\/en\/docs\/why-crvi-analysis-in-dry-paint-other-analysis-required\/","title":{"rendered":"Why Cr(VI) analysis in dry paint requires different analysis"},"content":{"rendered":"<div class=\"post-content clearfix\"><div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column width=&#8221;1\/1&#8243;][vc_column_text uncode_shortcode_id=&#8221;451522&#8243;]<\/p>\n<h3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\">Cr(VI) in paint: a well-known problem with an underestimated risk<\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">Chromium-6 (Cr(VI)) was used for years as a pigment and corrosion protector in various paint systems. Most people associate it with zinc-rich epoxy paints on steel structures, bridges, and locks, and that&#8217;s correct. But Cr(VI) is found in almost all types of paint layers: on wood, on concrete, in wall paint, and in decorative paint systems. In practice, we encounter it in a significant portion of the wood samples, roughly ten to fifteen percent, and concrete paint and other architectural applications are no exception.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">This means that the risk is not limited to heavy industry or infrastructure. It occurs everywhere historical paint layers are being worked on, removed, or demolished, in factories, in offices, in homes, and in public buildings. During all these activities, employees and the environment can be exposed to this carcinogen.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">To assess and control that exposure, a reliable measurement of the Cr(VI) concentration in the paint layer is essential. Without a good measurement, a substantiated risk assessment is not possible, and protective measures cannot be determined proportionally.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">The problem is that reliably measuring Cr(VI) in dry paint is analytically exceptionally difficult. And that this is too little recognized in practice.<\/p>\n<div>\n<div class=\"standard-markdown grid-cols-1 grid [&amp;_&gt;_*]:min-w-0 gap-3\">\n<h3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\">The standard: NEN 5617 and the well-known shortcomings<\/h3>\n<\/div>\n<\/div>\n<div>\n<div class=\"standard-markdown grid-cols-1 grid [&amp;_&gt;_*]:min-w-0 gap-3\">\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">In the Netherlands, NEN 5617:2022 is the only published national standard for Cr(VI) analysis in dry paint layers. The standard is widely accepted as a reference method and is frequently used by clients and laboratories.<\/p>\n<\/div>\n<\/div>\n<div>\n<div class=\"standard-markdown grid-cols-1 grid [&amp;_&gt;_*]:min-w-0 gap-3\">\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">What is less well known is that NEN 5617 itself already demonstrates in the round robin test underlying the standard that the method has serious shortcomings in matrices with zinc. Zinc is one of the most common components in industrial paint systems. The results from that ring study, published in the standard itself, make this crystal clear.<\/p>\n<\/div>\n<\/div>\n<div>\n<div class=\"standard-markdown grid-cols-1 grid [&amp;_&gt;_*]:min-w-0 gap-3\">\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">In a paint sample without zinc, the participating laboratories achieved an average recovery of 58%. That means that almost half of the present Cr(VI) is not measured back without any matrix interference. In paint sample two, with a zinc content of 5,000 mg\/kg, the average recovery dropped to 42%. In paint sample three, with 50,000 mg\/kg of zinc, an average of only 39% remained.<\/p>\n<\/div>\n<\/div>\n<div>\n<div class=\"standard-markdown grid-cols-1 grid [&amp;_&gt;_*]:min-w-0 gap-3\">\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">These are not the results of a failing method in the hands of weak laboratories. These are the results of the ring test that validates the standard itself, conducted by multiple certified laboratories. NEN 5617 recognizes this and explicitly classifies the method as semi-quantitative. However, the method is regularly used in practice as a basis for quantitative conclusions about exposure and risk.<\/p>\n<h3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\">Why zinc is so problematic<\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">Zinc is present in dry paint as metallic zinc or as a zinc compound. It is a strongly reducing metal. As soon as a paint sample is processed and extracted in the laboratory, the zinc and Cr(VI) dissolve simultaneously. Zinc then chemically converts Cr(VI) to Cr(III), the harmless and non-hazardous form of chromium. This process is quick and irreversible. The higher the zinc content, the more Cr(VI) is lost even before the actual measurement takes place.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">This makes the analysis of Cr(VI) in zinc-rich paint a race against time and chemistry. Methods that do not take this into account do not measure what actually is, but what is left after the reduction.<\/p>\n<h3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\">What the SEEF method does differently<\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">The SEEF method has been specifically developed to solve this problem. By means of a patented technique, Cr(VI) is actively stabilized throughout the entire analysis process. As a result, the Cr(VI) concentration remains intact from sample preparation to final measurement, even in the presence of high concentrations of zinc and other reducing components.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">The results speak for themselves. Where the six participating laboratories in the NEN ring study averaged a recovery of 39% for a paint sample with 50,000 mg\/kg zinc, the SEEF method consistently measures more than 80% for this same type of samples. In the paint samples from the ring study, SEEF achieved a recovery of 92%, 90%, and 81%, compared to the averages of 58%, 42%, and 39% of the NEN method.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">To further map the effect of zinc, SEEF conducted additional research in which one of the paint samples was supplemented with an extra 450,000 mg\/kg of metallic zinc, a concentration that almost no other laboratory would be able to analyze. The SEEF method achieved a recovery of 81% even under those extreme conditions.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">Even compared to another accredited method from a different laboratory, the SEEF method shows a clearly better performance. At a zinc concentration of 16% in the matrix, the NEN 5617 method yielded a recovery of 0.2%. The other accredited method came out at 6.5%. The SEEF method measured 35.3% under exactly the same conditions.<\/p>\n<h3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\">What this means in practice<\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">An underestimation of Cr(VI) in a paint sample has direct consequences. If the actual concentration is higher than measured, exposure calculations become too optimistic, protective measures are undersized, and employees face a greater risk than what the work plan is based on.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">In infrastructure projects where decisions are made about demolition, renovation, or protective measures based on Cr(VI) analyses, the quality of those analyses is not a technical detail. It is a direct determinant of health risk and legal liability.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">A measurement that reports 40% of the actual Cr(VI) content is not a measurement with a wide margin of uncertainty. It&#8217;s a justification that doesn&#8217;t add up.<\/p>\n<h3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\">How SEEF helps you with Cr(VI) in dry paint<\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"><strong>Laboratory analysis (DP01) \u2013 quantitative determination<\/strong> With the SEEF method, we reliably determine how much Cr(VI) is present in the paint layer, even in zinc-rich and complex coating systems. Based on this analysis, you can make a well-founded risk assessment and determine appropriate control measures.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"><strong>Combination analysis (DP03 and DP05)<\/strong> In addition to Cr(VI), we also determine the concentrations of zinc, aluminum, lead, and other relevant elements in the paint layer. This provides a complete picture of the composition and helps in interpreting the Cr(VI) results in the context of the matrix.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"><strong>Exposure measurements<\/strong> Additionally, we carry out professional air measurements to quantify the actual exposure to Cr(VI) during demolition work or maintenance, essential for demonstrable compliance with the Occupational Health and Safety Regulation.<\/p>\n<h3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\">Why this matters<\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">Cr(VI) is one of the few substances for which there is a legally binding limit value in European labor legislation that has only become stricter in recent years. The enforcement by the Dutch Labor Inspectorate is increasing, and clients are being increasingly held accountable for the quality of their risk assessments.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">An analysis that consistently yields low values offers no protection in that light. It creates liability.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">The SEEF method gives you the only result that matters: a measurement that reflects reality.<\/p>\n<p>Questions about your specific situation?\u00a0 <a href=\"https:\/\/seefbv.com\/contact\/en\">contact<\/a>\u00a0 us! Get in touch with our team or request a quote.<\/p>\n<\/div>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column width=&#8221;1\/1&#8243;][vc_column_text uncode_shortcode_id=&#8221;451522&#8243;] Cr(VI) in paint: a well-known problem with an underestimated risk Chromium-6 (Cr(VI)) was used for years as [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"doc_category":[57],"glossaries":[],"doc_tag":[],"class_list":["post-5961","docs","type-docs","status-publish","hentry","doc_category-crvi-analysis-explanation"],"year_month":"2026-08","word_count":1150,"total_views":"15","reactions":{"happy":"0","normal":"0","sad":"0"},"author_info":{"name":"Ferdy de Smet","author_nicename":"ferdy","author_url":"https:\/\/seefbv.com\/en\/author\/ferdy\/"},"doc_category_info":[{"term_name":"Analysis and interpretation","term_url":"https:\/\/seefbv.com\/en\/docs-category\/crvi-analysis-explanation\/"}],"doc_tag_info":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.0 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Measuring Cr(VI) in Paint: Why NEN 5617 Fails with Zinc | SEEF<\/title>\n<meta name=\"description\" content=\"Standard NEN 5617 misses up to 60% of Cr(VI) in zinc-rich paint. Discover why, and how SEEF&#039;s method achieves up to 92% recovery.\" \/>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Why Cr(VI) analysis in dry paint requires different analysis\" \/>\n<meta property=\"og:description\" content=\"Standard NEN 5617 misses up to 60% of Cr(VI) in zinc-rich paint. Discover why, and how SEEF&#039;s method achieves up to 92% recovery.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/seefbv.com\/en\/docs\/why-crvi-analysis-in-dry-paint-other-analysis-required\/\" \/>\n<meta property=\"og:site_name\" content=\"SEEF B.V.\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-30T12:15:51+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/seefbv.com\\\/en\\\/docs\\\/why-crvi-analysis-in-dry-paint-other-analysis-required\\\/\",\"url\":\"https:\\\/\\\/seefbv.com\\\/en\\\/docs\\\/why-crvi-analysis-in-dry-paint-other-analysis-required\\\/\",\"name\":\"Measuring Cr(VI) in Paint: Why NEN 5617 Fails with Zinc | SEEF\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/seefbv.com\\\/en\\\/#website\"},\"datePublished\":\"2026-04-06T06:30:11+00:00\",\"dateModified\":\"2026-06-30T12:15:51+00:00\",\"description\":\"Standard NEN 5617 misses up to 60% of Cr(VI) in zinc-rich paint. Discover why, and how SEEF's method achieves up to 92% recovery.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/seefbv.com\\\/en\\\/docs\\\/why-crvi-analysis-in-dry-paint-other-analysis-required\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/seefbv.com\\\/en\\\/docs\\\/why-crvi-analysis-in-dry-paint-other-analysis-required\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/seefbv.com\\\/en\\\/docs\\\/why-crvi-analysis-in-dry-paint-other-analysis-required\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/seefbv.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Docs\",\"item\":\"https:\\\/\\\/seefbv.com\\\/en\\\/docs\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Why Cr(VI) analysis in dry paint requires different analysis\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/seefbv.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/seefbv.com\\\/en\\\/\",\"name\":\"SEEF B.V.\",\"description\":\"Chroom-6 specialisten\",\"publisher\":{\"@id\":\"https:\\\/\\\/seefbv.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/seefbv.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/seefbv.com\\\/en\\\/#organization\",\"name\":\"SEEF B.V.\",\"url\":\"https:\\\/\\\/seefbv.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/seefbv.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/seefbv.com\\\/en\\\/en\\\/wp-content\\\/uploads\\\/sites\\\/6\\\/2025\\\/11\\\/Groenblauw_seef_groot.png\",\"contentUrl\":\"https:\\\/\\\/seefbv.com\\\/en\\\/en\\\/wp-content\\\/uploads\\\/sites\\\/6\\\/2025\\\/11\\\/Groenblauw_seef_groot.png\",\"width\":2000,\"height\":757,\"caption\":\"SEEF B.V.\"},\"image\":{\"@id\":\"https:\\\/\\\/seefbv.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/nl.linkedin.com\\\/company\\\/seef-bv\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Measuring Cr(VI) in Paint: Why NEN 5617 Fails with Zinc | SEEF","description":"Standard NEN 5617 misses up to 60% of Cr(VI) in zinc-rich paint. Discover why, and how SEEF's method achieves up to 92% recovery.","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"en_GB","og_type":"article","og_title":"Why Cr(VI) analysis in dry paint requires different analysis","og_description":"Standard NEN 5617 misses up to 60% of Cr(VI) in zinc-rich paint. Discover why, and how SEEF's method achieves up to 92% recovery.","og_url":"https:\/\/seefbv.com\/en\/docs\/why-crvi-analysis-in-dry-paint-other-analysis-required\/","og_site_name":"SEEF B.V.","article_modified_time":"2026-06-30T12:15:51+00:00","twitter_card":"summary_large_image","twitter_misc":{"Estimated reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/seefbv.com\/en\/docs\/why-crvi-analysis-in-dry-paint-other-analysis-required\/","url":"https:\/\/seefbv.com\/en\/docs\/why-crvi-analysis-in-dry-paint-other-analysis-required\/","name":"Measuring Cr(VI) in Paint: Why NEN 5617 Fails with Zinc | SEEF","isPartOf":{"@id":"https:\/\/seefbv.com\/en\/#website"},"datePublished":"2026-04-06T06:30:11+00:00","dateModified":"2026-06-30T12:15:51+00:00","description":"Standard NEN 5617 misses up to 60% of Cr(VI) in zinc-rich paint. Discover why, and how SEEF's method achieves up to 92% recovery.","breadcrumb":{"@id":"https:\/\/seefbv.com\/en\/docs\/why-crvi-analysis-in-dry-paint-other-analysis-required\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/seefbv.com\/en\/docs\/why-crvi-analysis-in-dry-paint-other-analysis-required\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/seefbv.com\/en\/docs\/why-crvi-analysis-in-dry-paint-other-analysis-required\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/seefbv.com\/en\/"},{"@type":"ListItem","position":2,"name":"Docs","item":"https:\/\/seefbv.com\/en\/docs\/"},{"@type":"ListItem","position":3,"name":"Why Cr(VI) analysis in dry paint requires different analysis"}]},{"@type":"WebSite","@id":"https:\/\/seefbv.com\/en\/#website","url":"https:\/\/seefbv.com\/en\/","name":"SEEF B.V.","description":"Chroom-6 specialisten","publisher":{"@id":"https:\/\/seefbv.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/seefbv.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/seefbv.com\/en\/#organization","name":"SEEF B.V.","url":"https:\/\/seefbv.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/seefbv.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/seefbv.com\/en\/en\/wp-content\/uploads\/sites\/6\/2025\/11\/Groenblauw_seef_groot.png","contentUrl":"https:\/\/seefbv.com\/en\/en\/wp-content\/uploads\/sites\/6\/2025\/11\/Groenblauw_seef_groot.png","width":2000,"height":757,"caption":"SEEF B.V."},"image":{"@id":"https:\/\/seefbv.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/nl.linkedin.com\/company\/seef-bv"]}]}},"knowledge_base_info":[],"knowledge_base_slug":[],"_links":{"self":[{"href":"https:\/\/seefbv.com\/en\/wp-json\/wp\/v2\/docs\/5961","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/seefbv.com\/en\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/seefbv.com\/en\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/seefbv.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/seefbv.com\/en\/wp-json\/wp\/v2\/comments?post=5961"}],"version-history":[{"count":4,"href":"https:\/\/seefbv.com\/en\/wp-json\/wp\/v2\/docs\/5961\/revisions"}],"predecessor-version":[{"id":5967,"href":"https:\/\/seefbv.com\/en\/wp-json\/wp\/v2\/docs\/5961\/revisions\/5967"}],"wp:attachment":[{"href":"https:\/\/seefbv.com\/en\/wp-json\/wp\/v2\/media?parent=5961"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/seefbv.com\/en\/wp-json\/wp\/v2\/doc_category?post=5961"},{"taxonomy":"glossaries","embeddable":true,"href":"https:\/\/seefbv.com\/en\/wp-json\/wp\/v2\/glossaries?post=5961"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/seefbv.com\/en\/wp-json\/wp\/v2\/doc_tag?post=5961"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}